Consistency between nasopharyngeal aspirates and bronchoalveolar lavage fluid in pathogen detection in children with pneumonia: an analysis of 533 cases
LUO Yong-Han, DAI Ji-Hong, GENG Gang, FU Wen-Long, LI Qu-Bei, SHU Chang
Department of Respiratory Diseases, Children's Hospital of Chongqing Medical University/Ministry of Education Key Laboratory of Child Development and Disorders/National Clinical Research Center for Child Health and Disorders/China International Science and Technology Cooperation Base of Child Development and Critical Disorders/Chongqing Key Laboratory of Pediatrics, Chongqing 400014, Chinacom)
Abstract:Objective To study the consistency between nasopharyngeal aspirates (NPA) and bronchoalveolar lavage fluid (BALF) in pathogen detection in children with pneumonia. Methods A retrospective analysis was performed on the data of pathogens detected in 533 children with pneumonia from February 2017 to March 2020. The paired McNemar's test was used to compare the difference in pathogen detection between NPA and BALF groups. The Kappa coefficient was used to analyze the consistency in pathogen detection between the two groups. Results NPA had a sensitivity of 28%, a specificity of 74%, a positive predictive value of 14%, and a negative predictive value of 91% in detecting bacteria, and a Kappa coefficient of 0.013 suggested poor consistency between NPA and BALF. NPA had a sensitivity of 52%, a specificity of 81%, a positive predictive value of 24%, and a negative predictive value of 94% in detecting viruses, and a Kappa coefficient of 0.213 suggested poor consistency between NPA and BALF. NPA had a sensitivity of 78%, a specificity of 71%, a positive predictive value of 49%, and a negative predictive value of 90% in detecting Mycoplasma pneumoniae, and a Kappa coefficient of 0.407 suggested moderate consistency between NPA and BALF. Conclusions There is poor consistency between NPA and BALF in the detection of bacteria and viruses, and clinicians should be cautious in diagnosing lower respiratory tract infection based on bacteria or viruses detected in NPA. There is moderate consistency between NPA and BALF in the detection of Mycoplasma pneumoniae, suggesting that it may be reliable to diagnose lower respiratory tract infection based on Mycoplasma pneumoniae detected in NPA, while comprehensive judgment in combination with clinical conditions is needed.
LUO Yong-Han,DAI Ji-Hong,GENG Gang et al. Consistency between nasopharyngeal aspirates and bronchoalveolar lavage fluid in pathogen detection in children with pneumonia: an analysis of 533 cases[J]. CJCP, 2021, 23(11): 1127-1131.
Wurzel DF, Marchant JM, Clark JE, et al. Respiratory virus detection in nasopharyngeal aspirate versus bronchoalveolar lavage is dependent on virus type in children with chronic respiratory symptoms[J]. J Clin Virol, 2013, 58(4): 683-688. PMID: 24125830. PMCID: PMC7173340. DOI: 10.1016/j.jcv.2013.09.016.
Hakki M, Strasfeld LM, Townes JM. Predictive value of testing nasopharyngeal samples for respiratory viruses in the setting of lower respiratory tract disease[J]. J Clin Microbiol, 2014, 52(11): 4020-4022. PMID: 25122864. PMCID: PMC4313242. DOI: 10.1128/JCM.01944-14.
Lachant DJ, Croft DP, McGrane Minton H, et al. Nasopharyngeal viral PCR in immunosuppressed patients and its association with virus detection in bronchoalveolar lavage by PCR[J]. Respirology, 2017, 22(6): 1205-1211. PMID: 28382762. PMCID: PMC7169060. DOI: 10.1111/resp.13049.
Boonyaratanakornkit J, Vivek M, Xie H, et al. Predictive value of respiratory viral detection in the upper respiratory tract for infection of the lower respiratory tract with hematopoietic stem cell transplantation[J]. J Infect Dis, 2020, 221(3): 379-388. PMID: 31541573. PMCID: PMC7107470. DOI: 10.1093/infdis/jiz470.
Su DQ, Li JF, Zhuo ZQ. Clinical analysis of 122 cases with mycoplasma pneumonia complicated with atelectasis: a retrospective study[J]. Adv Ther, 2020, 37(1): 265-271. PMID: 31707714. DOI: 10.1007/s12325-019-01129-8.