Therapeutic efficacy of volume-guaranteed high frequency oscillation ventilation on respiratory failure in preterm infants with a gestational age of 28-34 weeks: a prospective randomized controlled study
WANG Lu-Chun, BAO Zhi-Dan, MA Yi-Zhe, NIU Li-Mei, TAO Ming-Yan
Department of Neonatology, Jiangyin Hospital Affiliated to Medical School of Southeast University, Jiangyin, Jiangsu 214400, China
Abstract:Objective To investigate the therapeutic efficacy of volume-guaranteed high frequency oscillation ventilation (HFOV-VG) versus conventional mechanical ventilation (CMV) in the treatment of preterm infants with respiratory failure. Methods A prospective study was conducted on 112 preterm infants with respiratory failure (a gestational age of 28-34 weeks) who were admitted to the Department of Neonatology, Jiangyin Hospital Affiliated to Medical School of Southeast University, from October 2018 to December 2022. The infants were randomly divided into an HFOV-VG group (44 infants) and a CMV group (68 infants) using the coin tossing method based on the mode of mechanical ventilation. The therapeutic efficacy was compared between the two groups. Results After 24 hours of treatment, both the HFOV-VG and CMV groups showed significant improvements in arterial blood pH, partial pressure of oxygen, partial pressure of carbon dioxide, and partial pressure of oxygen/fractional concentration of inspired oxygen ratio (P<0.05), and the HFOV-VG group had better improvements than the CMV group (P<0.05). There were no significant differences between the two groups in the incidence rate of complications, 28-day mortality rate, and length of hospital stay (P>0.05), but the HFOV-VG group had a significantly shorter duration of invasive mechanical ventilation than the CMV group (P<0.05). The follow-up at the corrected age of 6 months showed that there were no significant differences between the two groups in the scores of developmental quotient, gross motor function, fine motor function, adaptive ability, language, and social behavior in the Pediatric Neuropsychological Development Scale (P>0.05). Conclusions Compared with CMV mode, HFOV-VG mode improves partial pressure of oxygen and promotes carbon dioxide elimination, thereby enhancing oxygenation and shortening the duration of mechanical ventilation in preterm infants with respiratory failure, while it has no significant impact on short-term neurobehavioral development in these infants.
WANG Lu-Chun,BAO Zhi-Dan,MA Yi-Zhe et al. Therapeutic efficacy of volume-guaranteed high frequency oscillation ventilation on respiratory failure in preterm infants with a gestational age of 28-34 weeks: a prospective randomized controlled study[J]. CJCP, 2023, 25(11): 1101-1106.
Chawanpaiboon S, Vogel JP, Moller AB, et al. Global, regional, and national estimates of levels of preterm birth in 2014: a systematic review and modelling analysis[J]. Lancet Glob Health, 2019, 7(1): e37-e46. PMID: 30389451. PMCID: PMC6293055. DOI: 10.1016/S2214-109X(18)30451-0.
Zhang L, Qiu Y, Yi B, et al. Mortality of neonatal respiratory failure from Chinese northwest NICU network[J]. J Matern Fetal Neonatal Med, 2017, 30(17): 2105-2111. PMID: 27651118. DOI: 10.1080/14767058.2016.1238894.
Sánchez-Luna M, González-Pacheco N, Belik J, et al. New ventilator strategies: high-frequency oscillatory ventilation combined with volume guarantee[J]. Am J Perinatol, 2018, 35(6): 545-548. PMID: 29694993. DOI: 10.1055/s-0038-1637763.
Sun H, Cheng R, Kang W, et al. High-frequency oscillatory ventilation versus synchronized intermittent mandatory ventilation plus pressure support in preterm infants with severe respiratory distress syndrome[J]. Respir Care, 2014, 59(2): 159-169. PMID: 23764865. DOI: 10.4187/respcare.02382.
Tuzun F, Deliloglu B, Cengiz MM, et al. Volume guarantee high-frequency oscillatory ventilation in preterm infants with RDS: tidal volume and DCO2 levels for optimal ventilation using open-lung strategies[J]. Front Pediatr, 2020, 8: 105. PMID: 32266185. PMCID: PMC7105735. DOI: 10.3389/fped.2020.00105.
Iscan B, Duman N, Tuzun F, et al. Impact of volume guarantee on high-frequency oscillatory ventilation in preterm infants: a randomized crossover clinical trial[J]. Neonatology, 2015, 108(4): 277-282. PMID: 26330156. DOI: 10.1159/000437204.
González-Pacheco N, Sánchez-Luna M, Ramos-Navarro C, et al. Using very high frequencies with very low lung volumes during high-frequency oscillatory ventilation to protect the immature lung. A pilot study[J]. J Perinatol, 2016, 36(4): 306-310. PMID: 26741575. DOI: 10.1038/jp.2015.197.
González-Pacheco N, Sánchez-Luna M, Chimenti-Camacho P, et al. Use of very low tidal volumes during high-frequency ventilation reduces ventilator lung injury[J]. J Perinatol, 2019, 39(5): 730-736. PMID: 30770883. DOI: 10.1038/s41372-019-0338-5.
Brown MK, Poeltler DM, Hassen KO, et al. Incidence of hypocapnia, hypercapnia, and acidosis and the associated risk of adverse events in preterm neonates[J]. Respir Care, 2018, 63(8): 943-949. PMID: 29615483. DOI: 10.4187/respcare.05801.