Abstract:Objective To study the applicability of Multi-Test Ⅱ prick device in the skin prick test (SPT) for allergens in children. Methods A total of 87 children with allergic diseases who attended the hospital between March and September, 2017 were enrolled as subjects. The SPT for six inhaled allergens and serum specific IgE (sIgE) measurement were performed for all children. SPT was performed with a single-headed device on the left forearm and Multi-Test Ⅱ prick device on the right forearm. ELISA was used to measure the serum level of sIgE. Visual Analog Scale (VAS) was used to assess the degree of pain during SPT. The three Methods were compared in terms of the detection rates of six allergens, and the sensitivity and specificity of Multi-Test Ⅱ prick device were analyzed. Results There were no significant differences in the detection rates of six allergens among the Multi-Test Ⅱ method, the single-headed method, and ELISA (P > 0.05). Compared with the single-headed method, the Multi-Test Ⅱ method had a sensitivity of 72.7% and a specificity of 78.2%. Compared with ELISA, the Multi-Test Ⅱ method had a sensitivity of 73.4% and a specificity of 77.5%. The Multi-Test Ⅱ method had a significantly lower degree of pain than the single-headed method (P < 0.05). Conclusions The Multi-Test Ⅱ method has high sensitivity and specificity and is easily accepted by children, but the test Results should be combined with children's medical history and serum level of sIgE when necessary.
WANG Ya-Ru,GUAN Hui,WANG Yan et al. Application of Multi-Test Ⅱ prick device in the skin prick test for allergens in children[J]. CJCP, 2018, 20(10): 835-839.
Carr WW, Martin B, Howard RS, et al. Comparison of test devices for skin prick testing[J]. J Allergy Clin Immunol, 2005, 116(2):341-346.
[5]
Bernstein DI. The skin prick test:"more than meets the eye"[J]. Ann Allergy Asthma Immunol, 2004, 92(6):587-588.
[6]
Dykewicz MS, Lemmon JK, Keaney DL. Comparison of the Multi-Test Ⅱ and Skintestor Omni allergy skin test devices[J]. Ann Allergy Asthma Immunol, 2007, 98(6):559-562.
[7]
Maniglia SF, Tsuru FM, Santos VC, et al. Sensitization profile to allergens in patients using Multi-Test Ⅱ[J]. Int Arch Otorhinolaryngol, 2014, 18(4):391-397.
[8]
Simons JP, Rubinstein EN, Kogut VJ, et al. Comparison of Multi-Test Ⅱ skin prick testing to intradermal dilutional testing[J]. Otolaryngol Head Neck Surg, 2004, 130(5):536-544.
Glovsky MM. Measuring allergen-specifc IgE:where have we been and where are we going?[J]. Methods Mol Biol, 2007, 378:205-219.
[16]
Masse MS, Granger Vallée A, Chiriac A, et al. Comparison of five techniques of skin prick tests used routinely in Europe[J]. Allergy, 2011, 66(11):1415-1419.
[17]
Dykewicz MS, Dooms KT, Chassaing DL. Comparison of the Multi-Test Ⅱ and Comfor Ten allergy skin test devices[J]. Allergy Asthma Proc, 2011, 32(3):198-202.
Oppenheimer J, Nelson HS. Skin testing:a survey of allergists[J]. Ann Allergy Asthma Immunol, 2006, 96(1):19-23.
[20]
Krouse JH, Sadrazodi K, Kerswill K. Sensitivity and specificity of prick and intradermal testing in predicting response to nasal provocation with timothy grass antigen[J]. Otolaryngol Head Neck Surg, 2004, 131(3):215-219.
[21]
Krouse JH, Shah AG, Kerswill K. Skin testing in predicting response to nasal provocation with alternaria[J]. Laryngoscope, 2004, 114(8):1389-1393.
[22]
Nelson HS, Lahr J, Buchmeier A, et al. Evaluation of devices for skin prick testing[J]. J Allergy Clin Immunol, 1998, 101(2 Pt 1):153-156.
[23]
Yoon IK, Martin BL, Carr WW. A comparison of two singleheaded and two multi-headed allergen skin test devices[J]. Allergy Asthma Proc, 2006, 27(6):473-478.
[24]
Heinzerling L, Mari A, Bergmann KC, et al. The skin prick test-European standards[J]. Clin Transl Allergy, 2013, 3(1):3.