Abstract Objective To investigate the value of abdominal ultrasound in diagnosing neonatal necrotizing enterocolitis(NEC) and its significance in evaluating the disease severity.Methods The clinical data of 84 neonates who were diagnosed with NEC between July 2013 and January 2015 were analyzed retrospectively.According to the modified Bell-NEC staging criteria, these neonates were divided into a suspected NEC group(n=44) and a confirmed NEC group(n=40);according to clinical prognosis, they were divided into a medical treatment and full recovery group(n=58) and a surgery/death group(n=26).The changes in the results of abdominal ultrasound and abdominal X-ray plain film were compared between groups.Results In the confirmed NEC group, abdominal ultrasound showed significantly higher detection rates of portal venous gas and dilatation of the intestine than abdominal X-ray plain film(PPConclusions Abdominal ultrasound is useful for the diagnosis of NEC.Ultrasonic findings can contribute to the prediction of the severity of NEC.
YANG Lei,XU Wei,LI Yong-Wei et al. Value of abdominal ultrasound in the diagnosis of neonatal necrotizing enterocolitis and evaluation of disease severity[J]. CJCP, 2016, 18(2): 108-112.
YANG Lei,XU Wei,LI Yong-Wei et al. Value of abdominal ultrasound in the diagnosis of neonatal necrotizing enterocolitis and evaluation of disease severity[J]. CJCP, 2016, 18(2): 108-112.
Neu J, Walker WA. Necrotizing enterocolitis[J]. N Engl J Med, 2011, 364(3):255-264.
[2]
Bohnhorst B. Usefulness of abdominal ultrasound in diagnosing necrotising enterocolitis[J]. Arch Dis Child Fetal Neonatal Ed, 2013, 98(5):F445-F450.
[3]
Silva CT, Daneman A, Navarro OM, et al. Correlation of sonographic findings and outcome in necrotizing enterocolitis[J]. Pediatr Radiol, 2007, 37(3):274-282.
[4]
Kim WY, Kim WS, Kim IO, et al. Sonographic evaluation of neonates with early-stage necrotizing enterocolitis[J]. Pediatr Radiol, 2005, 35(11):1056-1061.
[5]
Muchantef K, Epelman M, Darge K, et al. Sonographic and radiographic imaging features of the neonate with necrotizing enterocolitis:correlating findings with outcomes[J]. Pediatr Radiol, 2013, 43(11):1444-1452.
[6]
Garbi-Goutel A, Brévaut-Malaty V, Panuel M, et al. Prognostic value of abdominal sonography in necrotizing enterocolitis of premature infants born before 33 weeks gestational age[J]. J Pediatr Surg, 2014, 49(4):508-513.
[7]
Shebrya NH, Amin SK, El-Shinnawy MA, et al. Abdominal ultrasonography in preterm necrotizing enterocolitis. Is it superior to plain radiography?[J]. Egypt J Radiol Nuclear Med, 2012, 43(3):457-463.
Kinoshita H, Shinozaki M, Tanimura H, et al. Clinical features and management of hepatic portal venous gas:four case reports and cumulative review of the literature[J]. Arch Surg, 2001, 136(12):1410-1414.
[10]
Bohnhorst B, Kuebler JF, Rau G, et al. Portal venous gas detected by ultrasound differenciates surgical NEC from other acquired neonatal intestinal disease[J]. Eur J Pediatr Surg, 2011, 21(1):12-17.
[11]
Staryszak J, Stopa J, Kucharska-Miassik I, et al. Usefulness of ultrasound examinations in the diagnosis of necrotizing enterocolitis[J]. Pol J Radiol, 2015, 80:1-9.
[12]
Coursey CA, Hollingsworth CL, Wriston C, et al. Radiographic predictors of disease severity in neonates and infants with necrotizing enterocolitis[J]. AJR Am J Roentgenol, 2009, 193(5):1408-1413.
[13]
Sharma R, Tepas JJ 3rd, Hudak ML, et al. Portal venous gas and surgical outcome of neonatal necrotizing enterocolitis[J]. J Pediatr Surg, 2005, 40(2):371-376.