PDF(565 KB)
Diagnostic accuracy of tandem mass spectrometry combined with artificial intelligence for neonatal methylmalonic acidemia and associated factors
Peng-Yue YAN, Yang YU, Shan JIANG, Hong-Wei LI, Hong-Li WU
Chinese Journal of Contemporary Pediatrics ›› 2026, Vol. 28 ›› Issue (4) : 464-469.
PDF(565 KB)
PDF(565 KB)
Diagnostic accuracy of tandem mass spectrometry combined with artificial intelligence for neonatal methylmalonic acidemia and associated factors
Objective To evaluate the diagnostic accuracy of tandem mass spectrometry (MS/MS) combined with artificial intelligence (AI) for neonatal methylmalonic acidemia (MMA), and to identify factors associated with diagnostic accuracy. Methods A total of 246 neonates with positive initial MMA screening at Qinhuangdao Maternal and Child Health Hospital from January 2019 to December 2024 were recalled for confirmatory testing. Using genetic diagnosis as the reference standard, all cases underwent MS/MS diagnosis, AI diagnosis, and combined diagnosis (MS/MS plus AI). Sensitivity, specificity, accuracy, and other diagnostic performance indices were calculated; agreement with genetic diagnosis was assessed; and multivariable logistic regression was performed to identify factors associated with diagnostic accuracy. Results The combined diagnosis yielded a sensitivity of 92.3%, a specificity of 97.0%, and an accuracy of 96.7%, with high agreement with genetic diagnosis (Kappa=0.733). The areas under the receiver operating characteristic curve for combined, MS/MS, and AI diagnoses were 0.914(95%CI: 0.867-0.935), 0.759(95%CI: 0.635-0.816), and 0.669(95%CI: 0.584-0.776), respectively; the area under the curve for the combined diagnosis was significantly higher than that for either MS/MS or AI alone (P<0.05). Lower levels of methionine, phenylalanine, ornithine, glycine, blood ammonia, and lactic acid, as well as abnormal electrophysiological findings, were independently associated with diagnostic accuracy (P<0.05). Conclusions MS/MS combined with AI shows high diagnostic accuracy for neonatal MMA. Lower levels of methionine, phenylalanine, ornithine, glycine, blood ammonia, and lactic acid and abnormal electrophysiological findings may affect the diagnostic accuracy of MMA.
Methylmalonic acidemia / Tandem mass spectrometry / Diagnosis / Accuracy / Neonate
| [1] |
|
| [2] |
|
| [3] |
李育霖, 孙萌, 李盼盼, 等. 新生儿甲基丙二酸血症生化筛查与基因筛查结果分析[J]. 中华实用儿科临床杂志, 2023, 38(1): 54-59. DOI: 10.3760/cma.j.cn101070-20221102-01249 .
|
| [4] |
|
| [5] |
|
| [6] |
|
| [7] |
|
| [8] |
陈重芬, 张耀东, 葛丽丽, 等. 甲基丙二酸血症伴同型半胱氨酸血症患儿65例的临床及MMACHC基因变异分析[J]. 中华医学遗传学杂志, 2023, 40(9): 1086-1092. DOI: 10.3760/cma.j.cn511374-20220621-00417 .
|
| [9] |
王文婷, 陈莲. 甲基丙二酸血症临床病理学分析[J]. 诊断病理学杂志, 2023, 30(3): 267-269. DOI: 10.3969/j.issn.1007-8096.2023.03.015 .
|
| [10] |
|
| [11] |
|
| [12] |
|
| [13] |
|
| [14] |
|
| [15] |
|
| [16] |
|
| [17] |
黄国英, 王天有. 儿科学[M]. 2版. 北京: 人民卫生出版社, 2022: 997.
|
| [18] |
张潇分, 王燕敏, 周卓, 等. 串联质谱法和高效液相色谱-串联质谱法及气相色谱质谱法联合诊断甲基丙二酸血症的价值[J]. 中华实用诊断与治疗杂志, 2024, 38(11): 1154-1158. DOI: 10.13507/j.issn.1674-3474.2024.11.014 .
|
| [19] |
|
| [20] |
| [21] |
|
| [22] |
|
| [23] |
|
| [24] |
赵玲玉, 陈振贺, 王也, 等. 探针电喷雾离子化质谱法结合人工智能建立肺腺癌术中良恶性快速诊断模型[J]. 中日友好医院学报, 2024, 38(4): 209-212. DOI: 10.3969/j.issn.1001-0025.2024.04.004 .
|
| [25] |
|
| [26] |
|
| [27] |
|
| [28] |
|
| [29] |
|
所有作者均声明无利益冲突。